page 18
Hostname is set at the factory to a default value. This can be changed
through the MCS.
The next 2 blocks show the username and password when connecting
using MCS. The default is admin/secret. These can be changed at the
MCS window.
A warning message is displayed on the front panel after the MCS
is used for conguration (Warning: Time of day Ops). This tells
anyone about to use the front panel that the MCS has been used for
conguration and using the front panel will reset the settings made
by the MCS.
Setting Sound Masking Levels
There is a discussion in the Introduction section for recommended
volume settings.
Settings within the recommended ranges should optimize speech
privacy without excessive distractions. Generally, set masking volumes
toward the high end of the range and adjust according to site
conditions and user preferences. If possible, measure the results with
a sound level meter and check for the achieved sound pressure level.
Adjust as necessary or judge by listening in the area.
Figure 10: The format of the panel for conguring masking. Z1 stands for zone 1
and it is currently set to mute.
Host Name
QT XX
Username
admin
Password
secret
Masking
Z1 Volume: Mute